DOC-0017-10-EN: AC20 Series PROFINET IO Option
28 (47) DOC-0017-10-EN-A 27.03.2023
Configure Process Data Mapping
Option 1: Using AC20 Input and output mapping tables
The parameter 2566 MASTERMAPPING must be set to FALSE to prevent the PLC from
overwriting the mapping.
Through the mapping tables from the keypad, DSE Lite or Webserver, add parameter numbers
into the appropriate table.
Note: If the first row of a table (input mapping or Output mapping) is empty or equal to 0, the table
will not be accessible and configurable from PLC.
In Tia portal drag and drop the appropriate input and output modules from device catalogue to the
AC20 slot then define the variable name.