PVSG User Guide
17
7. Installation
Because every system is dierent, it is not feasible to provide detailed installation instructions that will be
suitable for every assembly. is chapter therefore provides only high-level guidelines on installing the
PVSG.
e vehicle manufacturer is responsible for creating procedures for mounting the CM0504 in
a vehicle during production assembly.
7.1. Mounting the PVSG to a Vehicle
It is up to the original equipment manufacturer (OEM) to ensure the product is securely mounted to the
vehicle.
e following guidelines are related to physically attaching the PVSG to a vehicle:
Secure the PVSG with bolts in all bolt holes using Hex Head 1/4”-20 or equivalent metric size (M6)
bolts.
e bolts should be tightened according to the recommended installation torque of 2.5 Nm (22 in-
lbs).
7.2. Mechanical Requirements
Review the following mechanical requirements before selecting a mounting location for the PVSG:
e PVSG should be mounted vertically so moisture will drain away from it.
e wire harness should have drip loops incorporated into the design to divert water away from the
PVSG.
e harness should be shielded from harsh impact.
e harness should connect easily to the connectors and have adequate bend radius.
e labels should be easy to read.
e PVSG should be in a location that is easily accessible for service.