Test procedure
Use a test stand that supplies
a ow of about 30 l/min. and
pressures of up to 300 bar.
A secondary ow of 3-5
l/min. at a pressure of 25
bar is required to supply
low pressure for externally
supplied controls.
EP control requires an
amplier supplying correct
current according to
specication.
Test
1. Fill housing with hydraulic
uid and start the pump in the
test stand.
2. Increase the pressure
with the restrictor valve on
the return line. Max allowed
pressure is 150 bar / 2150 psi.
3. Check the drain ow and
compare with the table.
V14-110, -160
4.0
Drain ow (l/min.), control not
activated.
Max 150 bar / 2150 psi
Max 220 bar / 3100 psi
Pump
V14
Servo oil
Servolja