7
Parker Hannin
Pump and Motor Division
Trollhättan, Sweden
Service Manual
Series V14
Bulletin HY30-5510-M1/UK
1. Frame size
110 - 110 cm³/rev
160 - 160 cm³/rev
2. Mounting ange
C - Cartridge (Cartridge version only -110)
I - ISO (ISO 3019/2)
Z - ZF (ISO 3019/2)
S - SAE (SAE J744c)
3. Shaft seal
V - FPM (uorocarbon)
4. Shaft end
C - DIN (ISO version)
D - DIN (ISO version)
S - SAE (SAE version)
5. Control
AC - Pressure compensator
AH - Pressure compensator with
hydraulic override
AD - Pressure compensator with electric
override and break defeat
EO - Electrohydraulic, two position
EP - Electrohydraulic, proportional
HO - Hydraulic, two-position
HP - Hydraulic, proportional
6. Control signal
E - External pressure (HO, HP)
H - 24 VDC (EO, EP)
L - 12 VDC (EO, EP)
I - Internal pressure (AC, AD, AH)
C - Pressure cut off (HP)
7. Control restrictor set
1 - 0,7
2 - 0,8
3 - 1,0 (standard)
4 - 1,2
5 - HPC
x - special
Ordering code
Example: V14 - 110 - S V S - EP I 1 A - P 350 - N - 00 - 110 / 032 - 210 - 000
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
8. Control modulating pressure/current
N - AC, AD: 0 bar; EP: non-selectable
current
A - 15 bar
1)
(AC, AD, AH, HP)
B - 25 bar
1)
(AC, AD, AH, HP)
C - 50 bar
1)
(AC, AD, AH)
D - 80 bar
1)
(AC, AD, AH)
9. Valve options
N - None
B - Brake valve and pressure relief valves
L - Flushing valve
P - Pressure relief valves
R - Optional valves
W - Load holding valve
10. Pressure relief valve opening pressure [bar]
or Flushing valve restrictor. See catalogue
HY30-8223/UK for further information.
000 - Without Pressure relief valves
11. Sensor options
N - None
C - Prepared for setting piston position
and shaft speed sensors
D - Speed and setting piston position
sensors
L - Setting piston position sensor
P - Prepared for speed sensor
T - Prepared for setting piston position
sensor
12. Factory issued number for special versions
13. Max displacement [cm
3
/rev]
14. Min displacement [cm
3
/rev]
15. Threshold setting
AC: select pressure between 100 and 350
[bar]
EO,EP: 12 VDC: 400 [mA]
24 VDC: 200 [mA]
HO,HP: Factory set at 10 [bar]
Is adjustable between 5 - 25 [bar]
16. Setting for pressure cut off (only HPC control)
HPC: Select cut off pressure between
75 - 400 [bar]
1)
Valid at max utilized displacement range
16