SPS010/0250 (60Hz)
6 Maintenance
a) The machine is designed and built to guarantee continuous opera-
tion; however, the life of its components depends on the maintenance
performed;
b) when requesting assistance or spare parts, identify the machine
(model and serial number) by reading the data plate located on the unit.
6.1 General instructions
! Before any maintenance, make sure:
the pneumatic circuit is no longer pressurized;
the dryer is disconnected from the main power supply
Y Always use the Manufacturer’s original spare parts: otherwise the
Manufacturer is relieved of all liability regarding machine malfunctioning
Y In case of refrigerant leakage, contact quali ed and authorized per-
sonnel.
Y The Schrader valve must only be used in case of machine malfunc-
tion: otherwise any damage caused by incorrect refrigerant charging will
not be covered by the warranty.
6.2 Refrigerant.
Charging: any damage caused by incorrect refrigerant replacement car-
ried out by unauthorized personnel will not be covered by the warranty.
Z
Y The equipment contains  uorinated greenhouse gases.
At normal temperature and pressure, the R5134a refrigerant is a colour-
less gas classi ed in SAFETY GROUP A1 - EN378 (group 2  uid accord-
ing to Directive PED 2014/68/EU)
GWP (Global Warming Potential) = 573.
! In case of refrigerant leakage, ventilate the room.
6.3 Preventive Maintenance Programme
To guarantee lasting maximum dryer ef ciency and reliability
Maintenance
Activity Description
Maintenance Interval
(standard operating condi-
tions)
Activity
Check
Service
Daily
Weekly
4 Months
12 Months
Check POWER ON indicator is lit.
Check control panel indicators.
Check condensate drain.
Clean condenser  ns.
Check electrical absorption.
Depressurize the dryer. Complete
drain maintenance.
Depressurize the dryer. Replace pre-
and post- lter elements.
The following are available (see par. 8.4):
a) compressor kits;
b) fan kits;
c) automatic expansion valve kits;
d) individual spare parts.
6.4 Dismantling
The refrigerant and the lubricating oil contained in the circuit must be
recovered in conformity with current local environmental regulations.
%
Recycling Disposal Z
structural work steel/epoxy-polyester resins
exchanger aluminium
pipes aluminium/copper
drain polyamide
exchanger insulation EPS (sintered polystyrene)
pipe insulation synthetic rubber
compressor steel/copper/aluminium/oil
condenser steel/copper/aluminium
refrigerant R513a
valves brass
electrical cables copper/PVC