Setting Communications and Unit Instructions
Steps Setup Instructions Display Notes
1
To set the RS485 communications or
change units from Metric to English,
visa versa, press the (
) or () buttons at
the same time, from the main screen, to
get into the settings menu.
SETTINGS MENU
SOFTWARE VERISON: 2.0
BAUD RATE: 19200
PARITY: EVEN
TEMPERATURE SCALE: ENGLISH
SELECT WITH ∨ ∧ PRESS (ENTER)
PRESS (MENU) TO RETURN
The baud rate and parity are for RS485 communication.
Default:
BAUD Rate: 19200
PARITY: EVEN
2
Use the (
) or () buttons to select
between the baud rate, parity or
temperature scale options.
SETTINGS MENU
SOFTWARE VERISON: 2.0
BAUD RATE: 19200
PARITY: EVEN
TEMPERATURE SCALE: ENGLISH
SELECT WITH ∨ ∧ PRESS (ENTER)
PRESS (MENU) TO RETURN
To change units select the temperature scale option.
3
After moving the selection bar to the
option you would like to change press
the (ENTER) button.
4
Use the (
) or () buttons to make
parameter changes within the selected
option.
SETTINGS MENU
SOFTWARE VERISON: 2.0
BAUD RATE: 19200
PARITY: EVEN
TEMPERATURE SCALE: METRIC
SELECT WITH ∨ ∧ PRESS (ENTER)
PRESS (MENU) TO RETURN
In this example English units was changed to Metric.
5
Press the (ENTER) button when done
making changes.
SETTINGS MENU
SOFTWARE VERISON: 2.0
BAUD RATE: 19200
PARITY: EVEN
TEMPERATURE SCALE: METRIC
SELECT WITH ∨ ∧ PRESS (ENTER)
PRESS (MENU) TO RETURN
This will take you back to the settings menu and the
(
) and () buttons can be used to make other option
selections.
6
Press the (MENU) button to return to the
main screen.
LIQUID SOL
VENT / WATER SO
L
TUE AUG/05/14 01:43PM PURGING
ACTIVE POINT: 01 05:56
ACTUAL TARGET
-6 °C 7.3 BAR VENT
6.0 BAR5.9 BAR RESET
CYCLE HISTORY
VENTS 019 TOTAL TIME 00:04:37
MODE: AUTO
Now the main screen is displayed in Metric units.
Setting Communications and Unit Instructions