Parking and access control equipment manufactured in the UK
PF9700 Automated Hinge Gate
Rev:8.2 -19
Installation, Operation &
Maintenance Manual
Manual Barriers
Auto Sliding barriers
Auto Bi-Fold barriers
Auto Rising Kerbs
Turnstiles
Auto Rising Bollards

Other manuals for Parking Facilities PF9700

Questions and Answers

  • T
    Tammy SantiagoAug 23, 2025
    Why is there an over-current in Parking Facilities PF9700 Fencing & Gates?
    • J
      jcampbellAug 23, 2025
      If your Parking Facilities Fencing & Gates system is showing an over-current error (either in the motor current or DC bus), there are several potential causes. First, verify that the motor data set is correct. If it isn't, correct the motor data set. Next, check the voltage increase/boost settings and adjust them if they are not properly set. Ensure that the motor is appropriately sized for the door. Finally, inspect the door for any sticking and resolve it. Addressing these potential issues will help resolve the over-current situation.
  • C
    Caleb MillerSep 5, 2025
    Why is the heatsink temperature out of range in Parking Facilities Fencing & Gates?
    • J
      Janet MccallSep 5, 2025
      If the heatsink temperature is outside of the working range Limit 1 in your Parking Facilities Fencing & Gates, it could be due to several reasons. There might be excessive load on the final stages or brake chopper, so reduce the load on these components. The ambient temperature might be too low for controller operation, so increase the ambient temperature. Additionally, the clock frequency of the final stage could be too high; lower the clock frequency of the final stage.
  • A
    Amy ShieldsSep 3, 2025
    What causes overvoltage in DC-bus in Parking Facilities PF9700?
    • S
      Samuel FieldsSep 3, 2025
      If you're experiencing overvoltage in the DC-bus of your Parking Facilities Fencing & Gates, it could be due to a few reasons. The input voltage supply might be too low, especially under load; increase the input voltage supply to address this. Alternatively, the load could be too great, or there might be a fault in the final stage or brake chopper; reduce the load or correct any final stage or brake chopper faults.
  • S
    starkannetteSep 1, 2025
    Why does Parking Facilities PF9700 detect a controller hardware reset?
    • C
      cody09Sep 1, 2025
      If a controller hardware reset is detected in your Parking Facilities Fencing & Gates, it could be due to excessive noise on the supply voltage. Inspect the supply voltage for excessive noise. Alternatively, the internal watchdog might have tripped; in this case, reset the internal watchdog. A RAM error could also be the cause; check the RAM and replace it if necessary.
  • G
    gsmithAug 31, 2025
    What causes overvoltage at the line supply input in Parking Facilities Fencing & Gates?
    • C
      Charles DeanAug 31, 2025
      If you're seeing an overvoltage at the line supply input for your Parking Facilities Fencing & Gates, it could be because the line supply voltage is too high. Reduce the line supply voltage to resolve this. Alternatively, the line supply might be fluctuating extremely; in this case, you should stabilize the line supply fluctuations.
  • A
    Anthony PhillipsAug 29, 2025
    How to resolve Overvoltage in DC-bus Limit 2 in Parking Facilities Fencing & Gates?
    • M
      Matthew CoxAug 29, 2025
      If you're encountering an overvoltage issue in the DC-bus Limit 2 of your Parking Facilities Fencing & Gates, consider these potential causes. There might be a brake chopper interference, defect, or it could be missing altogether; inspect and fix any brake chopper issues. The feed voltage may be too high, so check and reduce it. Also, the motor might be feeding back too much energy in generator mode, meaning the door motion energy can't be sufficiently brought down; implement measures to manage this energy feedback.
  • Z
    Zachary BarnesAug 27, 2025
    What causes Motor / DC-bus overcurrent Limit 2 in Parking Facilities PF9700?
    • C
      Christopher LeonardAug 28, 2025
      If your Parking Facilities Fencing & Gates experiences a Motor / DC-bus overcurrent Limit 2 error, it could stem from a few reasons. First, make sure the motor data set is correct. If not, correct it. Next, check the voltage increase/boost settings, adjusting them if they're not properly configured. Also, verify that the motor is appropriately sized for the door. Lastly, inspect the door for any sticking issues and resolve them. By addressing these potential causes, you can troubleshoot the overcurrent issue.
  • V
    victoria67Aug 27, 2025
    Why is the rotational direction wrong in Parking Facilities Fencing & Gates?
    • E
      Elizabeth MurrayAug 27, 2025
      If the rotational direction detected by your Parking Facilities Fencing & Gates system deviates from what's expected, here are a few things to check. If you're using incremental encoders, the Channel A and B connections might be reversed; if so, reverse them. The motor rotation direction could also be reversed compared to the calibration setting, in which case you should teach in the limits again. Too much 'pancaking' when starting could also be the reason, which means you should adjust boost as necessary.
  • R
    Ronald StewartAug 25, 2025
    How to fix 'run time exceeded' error in Parking Facilities Fencing & Gates?
    • W
      Whitney McgeeAug 25, 2025
      If the Parking Facilities Fencing & Gates system exceeds the run time during opening, closing, or deadman operation, it means the current motor run time has surpassed the set maximum. This could be because the door is sticking or blocked. The solution is to check the motor run time settings and ensure the door isn't obstructed.

Summary

Introduction and Warnings

Important Safety Notice

Crucial safety advice for gate operation and user responsibilities.

How to Use This Manual

Guidance on effectively reading and understanding the manual's content.

Delivery, Transport & Movement

Health and Safety in Goods Movement

Guidelines and project aims for reducing injuries during goods movement.

Component Identification

Manual Release Guide

First Operation Manoeuvres

Key Switch and Panel Operation

Instructions for operating the gate using the key switch and control panel buttons.

Panel Usage Guide

Troubleshooting Guide

Wiring Diagram

Input Parameter Configuration

Input Functions and Contact Types

Details on configuring input functions, unit range, and contact types.

Output Parameter Configuration

Output Relay Switching Conditions

Details on configuring output relay switching conditions and behavior.

Loop Detector Settings

Loop Detector Layouts and Installation

Configuration and installation guidance for loop detector layouts.

Electrical Troubleshooting Guide

Mechanical Troubleshooting Guide

Potential Hazard Areas

Installation;Commissioning Checklist

Service Log

Commissioning Certificate

Electronics Certificate

Certificate of Conformity

PF9700 A Technical Specifications

Electric Motor Details

Specifications for the 400v 3-phase braked electric motor.

Geared Motor Specifications

Technical details of the worm and wheel geared motor unit.

Parking Facilities PF9700 Specifications

General IconGeneral
BrandParking Facilities
ModelPF9700
CategoryFencing & Gates