RP-330 Technical Manual
11
1.8 Internal Buffer
1) Receive buffer: 20 K Bytes
1.9 Electrical Characteristics
1) Supply voltage: +24 VDC ± 7%
2) Current consumption (at 24V):
Operating: Approx. 1.5A(at ASCII Printing)
Peak:Approx. 10A(at print duty 100%, For 10 seconds or less)
Stand-by: Approx. 0.03A
1.10 EMI and Safety Standards Applied
1) Europe: EN55022 : 2006+A1 : 2007 (CLASS B)
EN55024 : 1998+A1 : 2001+A2 : 2003
EMS EN61000-3-2, EN61000-3-3
Safety Standard: UL 60950-1
2) North America: EMI - FCC Part#15 Class A
Safety Standards- UL60950-1
1.11 Reliability
1) MCBF: 60 million lines
(based on an average printing rate of 12.5% with paper thickness in the range 65
to 75 ).
35 million lines
(based on an average printing rate of 12.5% with paper thickness in the range 76
to 150 )
2) Cutter Life: the cutter performs 1,500,000 cuts with thickness 65 , and/or 300,00cuts with
thickness 100 to the paper
1.12 Environmental Conditions
1) Temperature: Operating: 5 to 45C
Storage: -20 to 60C
(except for paper)
2) Humidity: Operating: 10 to 90%RH
Storage: 10 to 90%RH (except for paper)