What should I do if my Passion R06SPA Heat Pump's exhaust temperature fails?
- MmarkruizSep 8, 2025
If the exhaust temperature fails, check or change the sensor.
What should I do if my Passion R06SPA Heat Pump's exhaust temperature fails?
If the exhaust temperature fails, check or change the sensor.
What should I do if my Passion R06SPA's water outlet temperature fails?
If the water outlet temperature fails, check or change the sensor.
What to do if my Passion R06SPA Heat Pump has no display on the LED wire controller?
If there is no display on the LED wire controller, the cause may be no power supply. Check whether the cable and circuit breaker are connected.
What should I do if my Passion R06SPA Heat Pump's DC Fan motor fails?
If the DC fan motor fails: 1. Check if the DC fan motor is damaged and change it if it is. 2. Check if the DC fan motor output port on the PCB has output. Change the PCB if there is no output.
What to do about too much ice on the evaporator of my Passion Heat Pump?
If there is too much ice on the evaporator: 1. Check the location of the heat pump, and eliminate all obstacles to assure good air ventilation. 2. Replace or repair the heat pump.
What to do if my Passion R06SPA Heat Pump displays a communication failure between the display and PCB?
If there is a communication failure between the display and PCB: 1. Check if the communication connection wire between the display and PCB is disconnected or has poor contact. Change the wire. 2. Check if the PCB or display is damaged. Change the corresponding part if it is.
What to do if my Passion Heat Pump has excessive exhaust temp protection?
If the heat pump shows excessive exhaust temp protection: 1. Replace the compressor discharge temperature sensor. 2. Reconnect or clean the compressor discharge temperature sensor and wrap it with insulation tape. Replace the controller or PC Board.
What to do if my Passion R06SPA shows a low pressure failure?
If a low pressure failure occurs: 1. Check for gas leakage and re-fill the refrigerant. 2. Replace the filter or capillary.
What causes short running in my Passion Heat Pump?
Short running can be caused by the fan not running. Check the cable connections between the motor and fan, and replace them if necessary.
What to do if my Passion R06SPA shows a high pressure failure?
If there is a high pressure failure: 1. Discharge redundant refrigerant from the heat pump gas system. 2. Clean the water exchanger or water filter.
General notes and important points regarding the installation of the heat pump.
Guidelines for selecting the optimal placement for the heat pump unit.
Instructions and diagrams for connecting the heat pump's electrical components.
Step-by-step procedure for starting and operating the heat pump for the first time.
Explanation of condensation formation on the evaporator fins during operation.
General features and capabilities of the LED display controller for the heat pump.
Diagram illustrating the control principle between the heat pump and the wire controller.
Detailed instructions on using the wire controller interface, its icons, and operating keys.
Procedure for manually activating the electric heater function of the heat pump.
Steps to initiate the enforced defrosting mode for the heat pump unit.
Procedure to reset the heat pump's settings back to their original factory defaults.
Instructions for accessing and adjusting various system parameters for optimal performance.
Information on error codes, their descriptions, and recommended solutions for system protections.
Troubleshooting common malfunctions and their solutions when the LED wire controller has no display.