EasyManua.ls Logo

Pavone Systems DAT 1400 - Page 40

Pavone Systems DAT 1400
88 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 38
C2ForN
COM2 PROTOCOL
Type of frame. For the SLAVE or MODBUS protocol you cannot select 7-bit data format (E-7-1 e O-7-1):
Values that can be selected:
n-8-1
n-8-2
E-7-2
E-8-1
o-7-2
o-8-1
Default: n-8-1
C2Addr.
COM2 ADDRESS
Communication address of the serial port:
Values from 1 to 32
Default: 1