PAGE 9
Intruder alarm integration
A dedicated port for input and output signals is provided when integrating a Net2 plus ACU with an alarm system.
Please see AN1035 - Integrating Net2 with an intruder alarm system < http://paxton.info/91 > or call Technical
Support for further information.
Arm - Arm conrmation Push Button - Wire across 0V and Arm.
Sense - Wire a voltage free loop across 0V and Sense to monitor the alarms current status.
Set - Wire a voltage free loop across COM and N.O. or N.C. to provide a set signal for the alarm.
Reader 1: Settings for Reader 1 and Keypad 1 on the ACU.
Reader 2: Settings for Reader 2 and Keypad 2 on the ACU.
Alarm: Contains settings for the different types of alarm.
Codes: Valid codes can be viewed, added and removed.
(Can only be viewed when a keypad is active).
Events: Shows the events for the control unit selected.
Name: Each reader can be named individually if required.
Reader type: Set the reader type, if applicable.
Keypad type: Set the keypad type, if applicable.
Token data format: Select the type of cards being used
on the system. (New formats can be created).
Reader operating mode: Set the operating mode.
Timed operating modes: A different operating
mode can be congured within a time window.
Reader action: Set the action required
when access is granted.
Software conguration
Door name: Name the Door.
Door open time: Set the door open time.
Unlock the Door during: Holds the door unlocked during this
timezone. - Set to 'At No Time' for normal user operation.
UL compatable readers
Part Type
373-110-US PROXIMITY P75 reader
373-120-US PROXIMITY P75 reader, screw connector
353-110-US PROXIMITY P50 reader
390-747-US PROXIMITY metal reader
390-727-US PROXIMITY metal reader, chrome
390-737-US PROXIMITY metal reader, brass
390-135-US PROXIMITY panel mount reader
Part Type
371-110-US TOUCHLOCK K75 keypad
371-120-US TOUCHLOCK K75 keypad, screw connector
372-110-US TOUCHLOCK K75 stainless steel keypad
372-120-US TOUCHLOCK K75 stainless steel, screw connector
375-110-US PROXIMITY KP75 keypad
375-120-US PROXIMITY KP75 keypad, screw connector

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paxton Net2 plus and is the answer not in the manual?

Paxton Net2 plus Specifications

General IconGeneral
ConnectivityEthernet, RS485
Power Supply12V DC
EnvironmentIndoor
Operating Voltage12V DC
CommunicationTCP/IP, RS485
Operating Temperature0°C to 45°C
Reader Capacity2
Door Capacity1
Users50, 000
Current Consumption150mA (typical)
Inputs2 (request to exit, door contact)
Number of Doors1
Outputs2 (door relay, aux relay)