PV 20a
4. Fix the burning chamber (8). For that you need to put a ceramic seal (4) on the narrower side of
the burning chamber and then put the camber through the door of the boiler in a way that the
rearward wall of the burning chamber would lean on the door of the boiler. Fixate the burning
chamber with two grub screws (10) to the flange.
Caution! The burning camber must be placed in a way that the burning grate will be as horizontal as
possible. The connection between the burner and the boiler must be tight in order to avoid any
leakage of smoke gases.
5. Connect the body of the burner to the burning chamber like it was done before disassembling in
step 2.
6. Fixate the halves of the burner with a M6 nut (9). The nut has to be rolled tight but not too hard.
The halves of the burner are connected correctly when there is no space between the mark on the
connecting tube (a line drawn on the tube with a dark marker) and the body of the burner.
7. Make sure the halves of the burner are connected correctly. Make sure that when looking through
the fire tube the igniter end tip is at the same level with the wall. The tube of the inner auger must
reach through its opening.
Caution! After the installation of the burner always make sure that the end of the igniter is
positioned through its opening and not stuck behind the dividing wall.
Pellet container
The burner, the auger and the pellet container are a common system. The size and the location of
the pellet container depend on the needs and possibilities of the specific boiler room. While choosing
the pellet container you must keep in mind that:
If the pellet container is in the same room as the boiler, then the size of the pellet container
must not exceed 500 liters (approx. 350kg).
The container must be made of fireproof materials.
The container must be positioned in a way that the raising angle of the feeding auger does
not exceed 45°.
It is advisable to use a container that can be closed with a cover.
11 www.pelltech.eu