PV 20a
Resetting safety thermostat
In case of overheating the burner flashes yellow indicator and displays message OVERHEAT. The
safety thermostat must be reset manually. Thermostat is located on the horizontal tube of inner
auger.
1. Make sure the burner has cooled down and disconnected from power supply.
2. Remove the cover by loosening 4 screws (2 on both sides)
3. Press small button on thermostat.
4. Connect power supply
5. Press OK for 5s
6. If indicator keeps flashing, you need to replace the thermostat.