OMNI-Test Laboratories, Inc.
BR – Average dry burn rate over full integrated test run, kg/hr
ASTM E2779 equation (3)
60 M
Bdb
θ
Where,
θ = Total length of full intergrated test run, min
Sample Calculation:
M
Bdb
= 5.57 kg
θ = 360 min
60 x 5.57
BR = 0.93
BR
=
360
kg/hr
BR
=