PelPro Pellet Stove • 7104-171A • 4/20/18
pelprostoves.com 25
Troubleshooting
Troubleshooting
Rumbling/whistling noise during operation
• Conrm exhaust path is clean and clear (Zone 1 & 3)
- Adjust air/fuel ratio using trim adjustment dial (See page 18 for trim adjustment
instructions)
Stove will not light
• Conrm rebox is clean and clear (Zone 1)
- Igniter is getting hot (glows orange)
• Inspect Stove body (Zone 2)
- Conrm fuel is in hopper, close lid securely
- Remove right side panel to access and conrm vacuum switch is clear and
connected at both ends
- Conrm all exhaust blower connections secure
- Conrm the feed assembly and motor are clean and clear of debris
• Conrm exhaust path is clean and clear (Zone 3)
1
Zone
1
Zone
3
Zone
3
Zone
2
Zone
2
Zone
Blockage Related
Black soot on outside of house
• Conrm exhaust path is clean and clear (Zone 1
and 3)
- Adjust air/fuel ratio using trim adjustment dial
(See page 23 for trim adjustment instructions)
• Ensure termination cap has at least 18” clearance
to reduce the effects of soot blow-back on home
exterior (ie. siding)—if not able, refer to page 10
for alternate installation options