OMNI-Test Laboratories, Inc.
C
s
- Concentration of particulate matter in tunnel gas, dry basis, corrected to standard conditions, g/dscf
ASTM E2515 equation (13)
Where:
K
2
= Constant, 0.001 g/mg
m
n
= Total mass of particulate matter collected in the sampling train, mg
V
m(std)
= Volume of gas sampled corrected to dry standard conditions, dscf
Sample calculation:
For Train 1:
2.7
57.46
C
s
=
0.00005 g/dscf
For Train 2
2.8
55.56
C
s
=
0.00005 g/dscf
For Ambient Train
0.0
55.43
C
r
=
0.000000 g/dscf
C
s
=
0.001 x
C
s
=
0.001 x
C
r
=
0.001 x
)(
2
stdm
n
s
V
m
KC
Control No. P-SFDK-0002, Effective date: 5/06/2016 File - 135PS040E PP70 Run 1, Tab - Example Calculations