OMNI-Test Laboratories, Inc.
PM
R
– Average particulate emissions for full integrated test run, g/hr
ASTM E2779 equation (5)
PM
R
= 60 (E
T
/θ)
Where,
E
T
= Tota particulate emissions, grams
θ = Total length of full intergrated test run, min
Sample Calculation:
E
T
(Dual train average)
= 2.96 g
θ = 360 min
PM
R
= 60
x (
2.96 / 360 )
PM
R
= 0.49
g/hr
Control No. P-SFDK-0002, Effective date: 5/06/2016 File - 135PS040E PP70 Run 1, Tab - Example Calculations