PelPro Pellet Stove • 7104-171A • 4/20/18
pelprostoves.com 7
Installing Your Stove
Installing Your Stove
Getting Ready (Continued)
Pellet Venting
Adding bends in the exhaust path restricts air ow,
reduces performance and provides a collection
point for ash deposits requiring more frequent
cleaning.
REQUIRED:
Use only 3” or 4” type “L” or “PL” pellet pipe.
C
C
CAUTION
• Do not connect to any air distribution duct or system
• Do not install a ue damper in the exhaust venting system of this
Stove
• Do not connect this Stove to a chimney ue serving another Stove
• The structural integrity of the manufactured home oor, wall and
ceiling/roof must be maintained
Pro Tip
This Stove can be installed with a 3 to 6 inch (76-152mm) Top Vent Offset Adapter Kit. The
3 to 6 inch (76-152mm) Top Vent Offset Adapter are tested to use 24 gauge single wall ue
connector or Listed double wall ue connector to Class A Listed metal chimneys, or masonry
chimneys meeting International Conference of Building Ofcials (ICBO) standards for solid
fuel Stoves.