4 - SETTINGS 3200 / 3210 /
3220 / 3230 TIMER
Set the number of days during which the valve must stay
in service. In order to do so, push the metallic tappet
outwards. The regeneration will happen at the set day at
2 A.M. Set the time of day by pushing on the clutch and
rotating the 24 hour wheel in order to put the time in front
of the arrow.
The 12 day version allows a regular interval
regeneration.
The 7 day version allows a regeneration based on the
days of the week, day 1 being Monday.
Timeclock Timer 3200 /12 days or 7 days
24h year
Programming wheel in number of days
between two regenerations.
Service position
Metered Timer delayed 3210 and immediate 3220
24 hour wheel
clutch
Time of day
display
White dot
Programmation
wheel in m
3
between
2 regenerations
Set the capacity that the softener can treat between two regenerations by lifting the
transparent disc with the programmation wheel with the m
3
label on the programming
wheel and set the number corresponding to the capacity of the softener next to the
white dot. Once the capacity is emptied, the regeneration will happen at
2 A.M. on the 3210 version or immediately on the 3220 version.
Regeneration triggered by an external
signal (straight contact) for 6 minutes.
Generally used on duplex and triplex
valve systems.