EasyManua.ls Logo

Pentair BLUEFURY LITE - Adjusting Hose Assembly Length; Sizing Lead Hose Section; Sizing Feed Hose Sections

Pentair BLUEFURY LITE
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
371885 (REV 12/2016) 6
English
Measure Deepest Part of Pool
Main Drain
Adjusng the Hose Assembly to Fit Pool
The hose assembly consists of: Two 10 . (3 m.) secons,
one 7.5 . (2.3 m.) secon, one 2.5 . (0.8 m.) secon and a
backup valve.
Important to the Performance of the Cleaner: Measure, cut,
and assemble the hose secons as described in Step 1 and Step
2. Use strong scissors or a sharp knife to cut the hoses. Be sure
to slide the oats out of the way when cung hose. Cut hose
ends as straight as possible.
Step 1: Sizing Hose Secon 1
1. Measure the deepest part of the pool. See Figure 3.
Note: The grate or domed main drain, at the boom of the
pool, is usually the deepest point. If the depth is greater
than 10 . [3 meters], do not cut the hose, and proceed
to Step 2.
2. If the pool depth is less than 10 . [3 meters], disconnect
the so light grey lead hose, labeled secon one, from the
back-up valve. Cut the lead hose so the length with back-up
valve is equal to the deepest part of the pool. See Figure 4.
Example: If the pool is 8.5 . [2.6 meters] deep, cut 1.5 .
[0.5 meters] o of the hose labelled secon one (since the
hose is 10 . [3 meters]).
3. Discard excess hose. Reconnect the newly cut lead hose to
the back-up valve on the feed hose. All three hose secons
should now be connected.
Step 2: Sizing Hose Secons 2 and 3
4. Aach the hose assembly to the wall ng. See Figure 5.
Then aach the wall ng (with hose) to the wall adaptor.
See Figure 5. Take the opposite end of the hose assembly
and walk to the farthest point of the pool from the wall
adaptor. To prevent over stretching the hose, rest the hose
on top of the pool water. Measure the excess hose length
(hose that extends beyond pool edge). This determines the
amount of hose to be cut from secons 2 and 3.
5. Disconnect feed hose assembly from the wall adaptor.
Disconnect secons 2 and 3 from the rst swivel closest
to the wall ng.
6. Cut half of the total excess hose length from each hose
labeled secon 2 and secon 3 (assembled with four
oats) equally. Both feed hose secons should be the
same length aer cung.
Example: If there is 6 . [1.8 meters]of excess hose. Cut 3
. [0.9 meters] o of secon 2 and secon 3. (Half of 6 .
[1.8 meters] = 3 . [0.9 meters] each)
If more than 3 . [0.9 meters] is cut from each hose secon,
remove one (1) oat from each hose secon.
Note: For large pools requiring extra hose lengths you will
need to purchase one (1) addional hose, P/N 360266 (10
. [3 meters] single hose). Aach extra hose secons at
the wall ng using supplied swivel and mender nuts.
Figure 6
Figure 5
Figure 3
Figure 4
Wall Fing
Hose Assembly
WALL FITTING
SWIVEL
SWIVEL
FLOATS
10 FT (3 M)
WHITE OR GREY
HOSE SECTION
MARKED SWIVEL
REMOVE EXCESS MATERIAL
FROM HOSE ON EITHER SIDE OF
MARKED SWIVEL AS DESCRIBED
IN STEPS 2 AND 3.
FLOATS
FLOATS
10 FT (3 M)
WHITE OR GREY
HOSE SECTION
10 FT (3 M)
SOFT HOSE
FARTHEST POINT OF
POOL PERIMETER
FROM WALL FITTING
BACKUP
VALVE
7½ FT. (2.3 M.) EXAMPLE DIMENSIONS
(Your Measurement May Differ)
NOT TO SCALE
Lead Hose Length = Deepest Part of Pool
Float
Quick
Connect Fing
(connects to
cleaner)
Swivel
Measuring the Lead Hose