Installing the Manual Air Relief Valve
1. Remove the High Flow™ Manual Air Relief Valve and the
pressure gauge from the accessories package included with your
Clean and Clear
®
Plus Cartridge Filter.
2. Thread the manual air relief valve into the threaded hole at the top
of the filter tank.
Note: Hand tighten only! Over tightening the valve can cause
damage to the tank or valve connection threads.
3. Verify that the valve is positioned to safely direct purged air or
water away from electrical equipment or anything that might be
damaged.
4. Remove the plug from the top of the manual air relief valve with a 9/16" wrench.
5. Wrap the pressure gauge connection threads with thread seal tape (two full wraps of tape will be enough).
6. Thread the pressure gauge into the top of the manual air relief valve. Hand tighten only!
7. Follow Start-up Instructions exactly (page 6).
VALVE
PLUG
PRESSURE
GAUGE
FILTER
TANK
Figure 2
The High Flow manual air relief valve and pressure gauge are
included with this filter to help ensure safe operation of the
equipment. Always maintain these components in good working condition.
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION. Water discharged from an improperly positioned
filter or valve can create an electrical hazard that can cause severe personal injury as well as damage
property.

Other manuals for Pentair CLEAN AND CLEAR PLUS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pentair CLEAN AND CLEAR PLUS and is the answer not in the manual?

Pentair CLEAN AND CLEAR PLUS Specifications

General IconGeneral
Filter TypeCartridge
Flow Rate150 GPM
Cartridge Quantity4
Max Pressure50 psi
MaterialFiberglass-reinforced composite
Inlet/Outlet Size2 inches
Cartridge MaterialPolyester
Filter AreaVaries by model (see product documentation)
DimensionsVaries by model (see product documentation)
WeightVaries by model (see product documentation)