27
IntelliChlor Electronic Chlorine Generator Installation and Users Guide
To install the IntelliChlor cell:
1. Using PVC glue, mount the PVC couplings to the plumbing pipe. Allow the glue to dry.
2. Mount the cell to allow access to the control panel. Install the cell onto the couplings.
Ensure the O-rings are seated properly.
3. Switch on the pump and visually inspect for leaks around the couplings.
Connecting the IC20, IC40 IC60 Cell Power Cable to the Power Center
After the cell installation is completed, connect the power cable to the Power Center:
1. Be sure that AC power is switched OFF before connecting the power cord to the Power Center.
2. Align the four (4) pins of the cell power cord connector with the socket on the bottom of the Power
Center and insert the connector. Turn the round socket nut until it locks the connector in place.
Connector socket nut.
To ce ll a ss em bly
WARNING - Switch OFF main system power to the Power Center before making any connections.
Connecting the Power Supply Cable to the IC15 Cell
After the IC15 cell installation is completed, connect the cell power cable to the Power Supply:
Align the four (4) pins of the cell power cord connector with the socket on the side of the Power
Supply and insert the connector. Turn the round socket nut until it locks the connector in place.
WARNING - Switch OFF main system power to the Power Center before making any connections.
Power Supply connector
IC15 Power Supply