Table 1: Troubleshooting (Continued)
Problem Possible Cause Corrective Action
Red LOW salt LED is
on.
Pool water needs salt. No chlorine is being
produced.
Add salt as described on pages 13, 14.
Red LOW SALT light on
and green CELL light
flashing
Salt level in pool water is low and may need
inspecting.
Check salt level, add if necessary to GOOD
level. Allow 24 hours for salt to mix in water. If
CELL light is still flashing after 24 hours,
remove and inspect cell and clean if necessary.
Red CHECK SALT light
is on
Not enough salt in pool.
Heavy Rainfall.
Leak in pool.
Add salt to pool to achieve 3400 ppm.
See page 13, 14.
Green GOOD salt light
is flashing
Too much salt in pool. May cause damage to
pool releated equipment and surrounding
surfaces.
Dilute pool water by draining some water, then
filling with fresh water
COLD WATER light is
red.
Water is below 52°F. The water temperature must be above 52°F to
produce chlorine.
CELL light does not
come on.
Chlorine Production set to 00%. Adjust CHLORINE PRODUCTION to desired
percentage.
Insufficient water flow. Cell is plugged with
debris, pump has lost prime.
Remove obstruction and/or clean cell. See
page 10. Prime pump if necessary.
Salt level below 2600 ppm. Add salt as described on pages 13, 14,
and 15.
CELL light is flashing
green.
Check salt level
Cell has calcium build-up and requires
cleaning.
Check water chemistry and balance.
NOTE metal content should be 0 ppm.
Add salt if necessary to maintain 3400 ppm
minimum.
Refer to Maintenance Procedure for acid
wash/cleaning. See "User Maintenance,"
on page 9.
Remove metals from water using chemical
solution.
Flow light is red. Pump fails to provide sufficient water flow. Check for correct operation of the pump, i.e.,
loss of pump prime or clogged strainer
baskets.
Closed valves. Check and correct all valve alignments.
Dirty filter. Follow filter cleaning procedures.
Obstruction in the Chlorinator cell. Remove cell for inspection. Follow cleaning
procedures. See "Electrolytic Cell Cleaning,"
on page 20.
IntelliChlor unit does
not have power.
Fuse in Power Center is open. Replace AC fuse, located at bottom of Power
Center.
No AC power to Power Center. Verify time clock is providing 110 VAC or 220
VAC to Power Center when active.
Transformer leads not wired correctly in Power
Center.
Verify transformer leads wired to AC source by
referring to wiring diagram decal on inside of
Power Center cover.
IntelliChlor Salt Chlorine Generator Installation and Users Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pentair INTELLICHLOR IC15 and is the answer not in the manual?

Pentair INTELLICHLOR IC15 Specifications

General IconGeneral
BrandPentair
ModelINTELLICHLOR IC15
CategoryLighting Equipment
LanguageEnglish

Related product manuals