OPERATING THE PUMP 14/20
PRIMING THE PUMP FOR THE FIRST TIME, OR AFTER SERVICE
The IntelliFlo® must be primed before starting the pump for the first time. To prime a pump
means filling the pump and suction pipe with water. This process evacuates the air from all
the suction lines and the pump. It may take several minutes to prime depending on the depth
of water, pipe size and length. It is easier to prime a pump if you allow all the air to escape
from the pump and pipes. The water cannot enter unless the air can escape. Pumps do not
hold prime, the pool piping system has that task.
Before removing the pump lid:
1. Press the Stop button if the pump is running before proceeding.
2. Disconnect the communication cable from the pump.
3. Disconnect main power supply
4. Close the gate valves in suction and discharge pipes.
5. Release all pressure from pump and piping system.
6. Never tighten or loosen the locking ring while the pump is operating.
CAUTION - To avoid permanent damage to the IntelliFlo® pump, before starting the pump,
fill the IntelliFlo® housing strainer with water so that the pump will prime correctly. If
there is no water in the strainer the pump will not prime.
• Do not allow the pump to run dry. Running the pump dry may damage the seals, causing
leakage and flooding.
• Do not add chemicals to the system directly in front of pump suction. Adding undiluted
chemicals may damage the pump and will void the warranty.
• Open gate valves before starting system.
• Be sure to release all air from filter and piping system.
• The IntelliFlo® pump is a variable speed pump. Typically the lower speeds are used
for filtration and heating. The higher speeds can be used for spa jets, water features,
and priming.
!
CAUTION - Before starting this procedure, first read the following:
!
WARNING - If the pump is being pressure tested, release all pressure before removing
trap cover. Do not block the pump suction while the pump is running. If a body part blocks
the pump suction it may cause severe or fatal injury. Small children using the pool must
ALWAYS have close adult supervision.
!
WARNING - FIRE and BURN HAZARD - The pump motor may run at a high temperatures.
To reduce the risk of fire, do not allow leaves, debris, or foreign matter to collect around
the pump motor. To avoid burns when handling the motor, shut off the motor and allow it
to cool for 20 minutes before trying to work on it. The IntelliFlo® provides an automatic
internal cutoff switch to protect the motor from heat damage during operation.
!
25