Priming (Continued)
3. Press the Select button. The factory default is set to priming “Enabled“.
4. To disable priming, press the Select button.
5. Use the Up arrow button. “Disabled” is displayed.
6. Press the Enter button.
7. Press the Down Arrow button. Screen will read “Max Priming Time”. Factory default is set
to 11 minutes.
8. Press the Select button to change the setting. The cursor will highlight the minutes column.
9. Use the Up or Down arrow button to change the time from 1 minute to 30 minutes..
10. Press the Enter button to save the setting.
11. Press the Down arrow button. The screen will read “Primed Sensitivity”. The default for
this setting being “1”.
12. Press the Select button to change the setting. The cursor will highlight the number.
13. Use the up or Down arrow button to change the time from 1% to 100%. Increasing the
number makes the Priming less sensitive.
14. Press Enter to save.
15. Press the Down arrow button. Screen will read “Priming Delay”. The default for this
setting is 20 seconds.
16. Press the Select button to change the Setting.
17. Use the Up or Down arrow button to change the setting from 1 second to 10 minutes.
Increasing the Priming Delay causes the pump to stay in the priming mode
longer thus increasing the amount of time the pump operates with the SVRS
off.
18. Press the Enter button to save the setting.
Note: To cancel a change, press the Escape button instead of the Enter button to exit without
saving.
19. Press the Escape button to exit.