Electrical Cost Overview
To calculate a system’s “Continuous Watts” use the following formula:
Amps X Volts X Power Factor = Continuous Watts
Examples:
1 HP E+ WhisperFlo = 7.4 amps X (230 Volt) X .90 PF = 1532 watts
1 HP Max E – Pro = 8.0 amps X (230 Volt) X .87 PF = 1600 watts
Once watts are computed, convert watts to kilowatts (kilo is 1000) and multiply this number by
kilowatt/hour cost.
1 watt = .01 Kilowatt
100 watts = .1 Kilowatt
1000 watts = 1 Kilowatt
1 HP E+ WhisperFlo 1532 watts or 1.532 Kilowatt x $.08 = $.122 per hour
1 HP Max-E-Pro 1600 watts or 1.600 Kilowatt x $.08 = $.128 per hour
The pump does not require calculation for continuous watts since it is displayed on the screen in all
modes. Just simply take the watts published on the screen, convert to kilowatts, and multiply by the
kilowatt hour. The formula is:
210 watts = .210 kilowatt X $.08 = $.016 per hour
Remember to also consider the amount of water moved for the cost incurred (Water to Wire
Efciency). The pump cannot be matched in today’s industry for ow versus continuous watts at any
speed by any other pump in pool. The Filter mode and ow control further assists in cost saving by
always allowing the pump to do the least amount of work at all times.
General Warnings
Never go inside the drive enclosure. There is a capacitor bank that holds a 230 VAC charge
even when there is no power to the unit.
The IntelliFlo
®
VS+SVRS Pump is not submersible.
The pump is capable of 174 GPM or 104 feet of head; use caution when installing and
programming to limit pumps performance potential with old or questionable equipment.
Code requirements for the electrical connection differ from state to state. Install equipment in
accordance with the National Electrical Code and all applicable local codes and ordinances.
There is no pressure limit in “Features” ow control.
The unit needs constant power it is built to turn itself on / off.
Always stop the unit before performing maintenance.
SVRS Blockage:
When the pump is in PRIMING MODE, the SVRS feature is DISABLED.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pentair INTELLIPRO VS+SVRS and is the answer not in the manual?

Pentair INTELLIPRO VS+SVRS Specifications

General IconGeneral
BrandPentair
ModelINTELLIPRO VS+SVRS
CategoryWater Pump
LanguageEnglish

Related product manuals