EasyManuals Logo

Pentair MASTERTEMP 125 User Manual

Pentair MASTERTEMP 125
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #40 background imageLoading...
Page #40 background image
P/N 475114 Rev. F 8/2020 MASTERTEMP 125 Pool and Spa Heater Installation and User’s Guide
| 31
Section 3. Troubleshooting
Initial Troubleshooting
Only qualified, trained service technicians with appropriate test equipment should service the heater. Remember
that all parts of the system affect heater operation. Before starting this troubleshooting procedure, make sure
that the pump is running correctly, that there are no blockages in the system, that the valves are correctly set
and that the time clock is correctly set and is running.
CAUTION: Installing the BLACK 120 volt plug in the control box and then connecting the heater to a
240 volt line will destroy the transformer, control broad, and ignition control module, and will void the
warranty. If you install the RED 240 volt plug and then connect the heater to a 120 volt line, the heater
will not operate. See page 17.
READ THE FOLLOWING INFORMATION CAREFULLY
1. Check the line voltage to your heater. This heater will operate on either 120 Volts AC or 240 Volts AC.
2. Remove the covers and check the 12-pin plug in the back of the control box. The plug must match the
voltage in the heater circuit.
3. If the 12-pin plug is not plugged into the back of the control box, select the correct plug from the bag in
the control box and plug it in. The BLACK plug is for 120 volts, the RED plug is for 240 volts.
Error and Fault Codes
Table 8. Heater Error and Fault Codes
Fault Condion
Error Code
Displayed
Note
Troubleshoo�ng
Water pressure switch
open
ERR PS
If water ow is established the
the error is cleared and normal
operaon is resumed.
No water ow thru
heater
Hi temperature limit
switch open
ERR HLS
When the temperature falls
below 135°F the error is cleared
and normal operaon is
resumed.
Water temperature aer
the 1
st
pass through the
heater exchanger is more
than 135°F.
Air ow switch open
ERR AFS
If adequate air ow through the
blower is established within 60
seconds the heater will resume
normal operaon. If the error is
not corrected within 60 seconds
the heater will need to turned
o by pressing the HEATER OFF
buon.
The blower is not on or
air thru it is being
restricted
Ignion Control Module
ERR IGN
To clear the error the HEATER
OFF buon must be pressed.
The Ignion Control
Module was not able to
ignite the heater.
Automac gas shuo
ERR AGS
The front panel buons will be
disabled. To reset the heater,
cycle power.
Water temperature aer
the 2
nd
pass thru the heat
exchanger is more than
140°F
Excessive stack ue
temperature
ERR SFS
The front panel buons will be
disabled. To reset the heater,
cycle power.
The temperature of the
stack ue is more than
480°F
Open stack ue sensor
E05
Shorted stack 
sensor
E06
The front panel buons will be
disabled. To reset the heater,
cycle power.
Follow diagram on page
37
Open water
temperature sensor
E01
To clear the error the HEATER
OFF buon must be pressed.
Follow diagram on page
35
Shorted water
temperature sensor
126
Follow diagram on page
35
Follow diagram on page
37
Section 3. Troubleshooting

Other manuals for Pentair MASTERTEMP 125

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pentair MASTERTEMP 125 and is the answer not in the manual?

Pentair MASTERTEMP 125 Specifications

General IconGeneral
BTU Output125, 000 BTU/hr
Fuel TypeNatural Gas or Propane
Ignition SystemElectronic
Minimum Flow Rate20 GPM
Maximum Working Pressure50 PSI
Efficiency82%
Water Connections1.5 inch
CertificationsANSI Z21.56
Voltage120V

Related product manuals