6
MY538-R (08-20-20)
PERFORMANCE & SPECIFICATIONS
SPECIFICATIONS
Power supply required................................................................................................................115V, 60 HZ.
Liquid temp. range.....................................................................................................................32°F to 130°F (55°C)
Individual branch circuit required (min.)......................................................................................20 Amps
Discharge....................................................................................................................................2"FNPT
NOTE:
Do not reduce size of discharge pipe or hose below 1-1/4” diameter. If discharge is too small, pump will overheat and fail prematurely.
ELECTRICAL & SWITCH SPECIFICATIONS
SERIES HP
MOTOR FULL
LOAD AMPS
INDIVIDUAL
BRANCH CIRCUIT
REQ. (AMPS)
AUTOMATIC SWITCH
TYPE
SWITCH SETTING IN INCHES WATER
LEVEL FOR:
ON OFF
MSW50T10BP-R 1/2 13.0A 20A 115 VAC Tethered Switch 16" 7"
PERFORMANCE
GPH(LPH) at total feet of lift
SERIES 0' 5' 10' 15'
NO FLOW AT
HEIGHT SHOWN
BELOW IN FEET
MSW50T10BP-R
9000
(34069)
7200
(27255)
5400
(20441)
3000
(11356)
18'