CBF1 PERFORMANCE DATA
Important Notice: Read performance data and compare the
capabilities of this system with your actual water treatment
requirements. It is recommended that the supply water be tested,
before installing a water treatment system, to determine your
water treatment needs.
CBF1 System with CB1 Filter Cartridge installed
This system has been tested according to NSF/ANSI 42 and 53 for
reduction of the substances listed below. The concentration of the
indicated substances in water entering the system was reduced to
a concentration less than or equal to the permissible limit for water
exiting the system, as specied in NSF/ANSI 42 and 53.
Substance
Inuent Challenge
Concentration
Maximum
Permissible
Product Water
Reduction
Requirements
Average
Reduction
Standard 42
Chlorine 2.0 mg/L ± 10% – ≥50% 97.4%
Standard 53
Cysts**
Minimum 50,000
Microsphere/L
– 99.95% >99.99%
** NSF/ANSI Standard 53 certied to reduce cysts such as Cryptosporidium and Giardia
by mechanical means.
CBF1 Test Conditions
Flow Rate CB1 cartridge 1.0 gpm
Filter Capacity CB1 cartridge 1,000 gallons
Inlet Pressure = 60 psi
pH = 7.5±1
Temperature = 68°F ± 5°F
Testing was performed under standard laboratory conditions;
actual performance may vary.
Operating Requirements
Pressure = 30-125 psi
Temperature = 40-100°F
Turbidity = 5 NTU Max.
EPA Est. No. 090375-Mex-001
Do not use with water that is microbiologically unsafe
or of unknown quality without adequate disinfection before or after
the system. Systems certied for cyst reduction may be used on
disinfected waters that may contain lterable cysts.
NOTE: Filter must be maintained according to manufacturer’s
recommendations, including replacement of lter cartridges.
The contaminants or other substances reduced by this water
treatment device are not necessarily in your water.