14
PN957 (25-06-20)
PROGRAMMING
Menu
Settings
Parameter Unit of Measure
Value
Description
Default Min. Max.
Ex Runtime
Excessive Runtime Detection _
Disabled Disabled
Enabled Enables or disables Excessive Runtime Detection.
Excessive Runtime Hours Hours 24 1 100
Number of hours Intellidrive can run before it faults on Excessive
Runtime.
Dry Run
Auto Restart Delay Minutes 10 Min 3 Min 60 Min
Time
Pentair Pentek Intellidrive
®
Constant Pressure Pump
Controller
waits to restart pump when Dry Run is detected.
Number of Resets 3 0 5
Number of tries Intellidrive attempts to restart pump when Dry
Run condition is detected.
Detection Time M:SS 15 Sec 5 Sec 10 Min Time the Intellidrive takes to recognize Dry Run condition.
Sensitivity PSI 10 0 300
Pressure value that Dry Run condition is detected at. Dry Run
fault will occur if this pressure cannot be met within Detection
Time window. Lower pressure = less sensitivity.
Fill Time M:SS 1 M 15 S 10 M
Time allowed to fill (prime) pipes during Auto Line Fill process.
Relates to Dry Run Sensitivity value. (Time starts after 55 Hz is
reached).
I/O
Digital Input 1 Unused
Selects operation of Intellidrive when terminal I1 or I2 is used.
Select between Unused, Run Enabled, Ext Fault, and Setpoint.
The Intellidrive will respond to selected command when voltage is
present at I1 or I2 terminal.
Digital Input 2 Unused
Relay Output Unused
Selects the operation of Intellidrive when terminal O1 is used.
Select between Unused, Run, and Fault. The Intellidrive closes
the Relay when Run or Fault is selected.
Over Press Over Pressure PSI 80 PSI 15 PSI 97 PSI
Sets Over Pressure Warning value. Change if higher than 80 PSI
system pressure is needed.
No Ground No Ground Detection Enabled
Disabled
Enabled
Selects whether Ground Detection parameter is Enabled or
Disabled. If Disabled is selected, it will revert back to Enabled
after 72 hours. Warning LED will flash entire time it is Disabled.
Reset Factory Reset No No Yes
Resets all parameters to factory defaults. Displays Setup Guide
after it is complete. Software version displayed here. Does not
clear fault log.
SW Update Software Update Disabled Disabled Enabled Used to update software, if necessary.
Table 5, Continued - Main Menu and Parameters

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pentair Pentek Intellidrive PID10 and is the answer not in the manual?

Pentair Pentek Intellidrive PID10 Specifications

General IconGeneral
BrandPentair
ModelPentek Intellidrive PID10
CategoryDC Drives
LanguageEnglish

Related product manuals