SOFTFLO 5600
SERVICE MANUAL
MANUAL DE SERVICIO
4002217
4002162

Table of Contents

Questions and Answers

  • S
    smithamandaAug 20, 2025
    What to do if my Pentair SOFTFLO 5600 Water Dispenser shows Error Code 2: Regen Failure?
    • L
      Lauren RiveraAug 20, 2025
      If your Pentair Water Dispenser displays Error Code 2, it means the system hasn't regenerated for over 99 days (or 7 days if set to Day-of-Week). To fix this, start a manual regeneration to clear the error. For metered systems, ensure it's measuring flow by checking the flow indicator while water is running. If no flow is measured, check the meter cable and its function. In Master Programming Mode, confirm the unit is correctly configured, including system capacity, day override, and meter identification. If it's a Day-of-Week system, ensure at least one day is set ON. Adjust settings as needed.
  • V
    Virginia PerryAug 21, 2025
    What does Error Code 0 mean on my Pentair Water Dispenser and how to fix it?
    • C
      Christina PetersonAug 22, 2025
      If your Pentair Water Dispenser is showing Error Code 0, which is a Cam Sense Error, it means the valve drive took more than 6 minutes to reach the next regeneration position. First, unplug the unit and check the powerhead. Make sure all cam switches are connected to the circuit board and working. Check the motor and drive train components for proper assembly and condition. Also, check the valve to ensure the piston moves freely. Replace or reassemble parts as needed. Plug the unit back in to see if it cycles to the next position. If the error returns, unplug it and contact technical support.
  • R
    Rachel SmithAug 25, 2025
    What does Error Code 1 mean on my Pentair SOFTFLO 5600 Water Dispenser and how do I fix it?
    • A
      April CastilloAug 25, 2025
      If your Pentair Water Dispenser displays Error Code 1, a Cycle Step Error, it means the control received an unexpected cycle input. Unplug the unit and check the powerhead. Verify all cam switches are connected and working properly. Enter Master Programming mode to check if the valve and system types are correctly set. Manually step the unit through regeneration to see if it functions correctly. If the error continues, unplug the unit and contact technical support.
  • J
    Jared WagnerAug 26, 2025
    How to fix Error Code 3: Memory Error on Pentair SOFTFLO 5600?
    • C
      Carla CarterAug 26, 2025
      If your Pentair Water Dispenser displays Error Code 3, it indicates a control board memory failure. To resolve this, perform a Master Reset and reconfigure the system using the Master Programming Mode. After reconfiguring, manually cycle the valve through a regeneration. If the error reappears, unplug the unit and contact technical support.
  • L
    Lisa StanleyAug 28, 2025
    Why does my Pentair SOFTFLO 5600 drain continuously?
    • K
      Kelly JohnsonAug 28, 2025
      To resolve continuous draining in your Pentair Water Dispenser, first check the timer program and control positioning to ensure the valve is programming correctly. If it's not positioning properly, replace the power head assembly. Also, inspect the bore for any foreign material by removing the power head assembly, remove any debris, and check the control in various regeneration positions. Finally, if there is an internal control leak, replace the seals and piston assembly.
  • B
    Brittney BassAug 29, 2025
    Why is my Pentair Water Dispenser not regenerating?
    • N
      nicholsjohnAug 30, 2025
      If your Pentair Water Dispenser isn't regenerating, ensure it has continuous electrical service by checking the fuse, plug, pull chain, or switch. If the timer is defective, replace it. Also, if there was a power failure, reset the time of day.
  • R
    Robert HowellSep 1, 2025
    Why is my Pentair Water Dispenser producing hard water?
    • S
      Sara CarrollSep 1, 2025
      If you're experiencing hard water with your Pentair Water Dispenser, first ensure the by-pass valve is closed. Check that there's enough salt in the brine tank, maintaining the salt level above the water level. Also, inspect the injector screen for any blockages and clean it if necessary. Ensure enough water flows into the brine tank by checking the fill time and cleaning the brine line flow control if it's plugged. If the hot water tank hardness, repeated flushing may be required. Check for leaks at the distributor tube, making sure it's not cracked and inspect the O-ring and tube pilot. Lastly, an internal valve leak may be the cause, requiring replacement of the seals, spacers, and/or piston.
  • J
    Jessica TaylorSep 3, 2025
    Why is my Pentair Water Dispenser using too much salt?
    • G
      Gregory OwensSep 3, 2025
      If your Pentair Water Dispenser is using too much salt, check the salt usage and salt setting to ensure it's properly configured. Also, check for excessive water in the brine tank.
  • M
    Melanie NelsonSep 5, 2025
    Why am I experiencing loss of water pressure with my Pentair SOFTFLO 5600 Water Dispenser?
    • E
      Evan EstradaSep 5, 2025
      If you're experiencing a loss of water pressure with your Pentair Water Dispenser, it could be due to iron buildup. Clean the line leading to the water conditioner. If the buildup is in the conditioner itself, clean the control and add mineral cleaner to the mineral bed, also increase the frequency of regeneration. If the inlet of the control is plugged due to foreign material from recent plumbing work, remove the piston and clean the control.
  • N
    nicolebentleySep 7, 2025
    Why is my Pentair SOFTFLO 5600 Water Dispenser losing mineral through the drain line?
    • E
      Eugene MorrisonSep 7, 2025
      If your Pentair Water Dispenser is losing mineral through the drain line, it could be due to air in the water system. Ensure your well system has a proper air eliminator control and check for a dry well condition. Also, check that the drain line flow control is properly sized and adjust the drain rate if needed.

Summary

Installing Water Softeners on Water Supplies Containing Iron

Electrical Specifications

Pre-Installation Checklist

Installation

Drain Requirements

Special Drain Line Situations

Modifications for drain lines that must rise above the control valve.

Model 5600 Installation and Start-Up Procedures

Timer Features

Timer Operation

Meter Immediate Control

Measures water usage and regenerates system when capacity is depleted.

Meter Delayed Control

Regenerates system after capacity depletion at programmed time.

Time Clock Delayed Control

Regenerates on a timed interval based on programmed regeneration time.

Day of the Week Control

Regenerates on a weekly schedule based on programmed days.

Master Programming Mode Chart

Master Programming Mode

Basic Settings

Includes time, entry/exit procedures, and system resets.

System Configuration

Sets display format, valve type, control type, and number of tanks.

User Programming Mode

Day Override

Sets the maximum days between regeneration cycles.

Regeneration Time

Sets the time of day for regeneration.

Feed Water Hardness

Enters the feedwater hardness for calculations.

Reserve Capacity

Sets the fixed reserve capacity for the system.

Current Day

Sets the current day of the week for scheduling.

Diagnostic Programming Mode

Flow Rate

Displays the current outlet flow rate of the unit.

Peak Flow Rate

Shows the highest flow rate measured since the last regeneration.

Hours in Service

Displays the total hours the unit has been in service.

Volume Used

Shows the total volume of water treated by the unit.

Reserve Capacity

Displays the system's calculated reserve capacity.

Software Version

Shows the installed software version on the controller.

Adjusting the Efficiency

Disinfection of Water Softeners

Adding Salt

Types of Salt

Recommended types of salt and substitutes for the softener.

Amount of Salt

Guidance on the recommended salt level in the brine tank.

System Assembly

Control Valve Drive Assembly

Control Valve Assembly

Service Instructions

Replacing Brine Valve, Injectors and Screen

Steps for replacing key components of the brine valve and injector assembly.

Brine Valve Replacement

Detailed instructions for replacing the brine valve component.

Injectors;Screen Replacement

Guide for replacing the injector nozzle, throat, and screen.

Timer Replacement

Procedure for replacing the timer assembly on the control valve.

Piston Assembly Replacement

Instructions for removing and replacing the piston assembly.

Water Conditioner Flow Diagrams

Service Position

Illustrates water flow through the unit during normal service operation.

Preliminary Rinse Position

Shows water flow during the preliminary rinse cycle.

Backwash Position

Depicts water flow during the backwash regeneration step.

Brine Position

Illustrates water flow during the brine draw and slow rinse cycle.

Maintenance and Repair

Lack of Treated Water (Intermittent)

Troubleshoots intermittent loss of soft water due to usage, chemistry, or regeneration frequency.

Lack of Treated Water (Constant)

Addresses constant loss of soft water from low salt, high consumption, or dirty screens.

Brine Tank Overflow

Identifies causes and solutions for brine tank overflow issues.