FLECK 5600SXT DOWNFLOW
SERVICE MANUAL
www.pentairaqua.com

Questions and Answers

  • J
    John Villarreal DDSAug 21, 2025
    What to do if Pentair Water Dispenser fails to regenerate?
    • P
      Paul DavisAug 21, 2025
      If your Pentair Water Dispenser isn't regenerating, it could be due to a few reasons: * An interruption in electrical service: Ensure permanent electrical service by checking the fuse, plug, pull chain, or switch. * A defective timer: Replace the timer. * A power failure: Reset the time of day.
  • M
    Michael TorresAug 25, 2025
    Why is there excessive water in the brine tank of my Pentair Water Dispenser?
    • S
      Stephen KempAug 25, 2025
      If you notice excessive water in the brine tank of your Pentair Water Dispenser, possible causes include: * A plugged drain line flow control: Clean the flow control. * A plugged injector system: Clean the injector and screen. * Timer not cycling: Replace the timer. * Foreign material in brine valve: Replace brine valve seat and clean valve. * Foreign material in brine line flow control: Clean brine line flow control.
  • J
    Jamie McconnellAug 26, 2025
    How to fix loss of water pressure in Pentair Water Dispenser?
    • S
      Samantha SantiagoAug 26, 2025
      A loss of water pressure in your Pentair Water Dispenser can be attributed to: * Iron buildup in the line to the water conditioner: Clean the line to the water conditioner. * Iron buildup in the water conditioner: Clean the control and add mineral cleaner to the mineral bed. Increase the frequency of regeneration. * A plugged inlet of the control due to foreign material: Remove the piston and clean the control.
  • A
    Albert CarlsonAug 27, 2025
    What to do if Pentair Water Dispenser fails to draw brine?
    • E
      ehartmanAug 28, 2025
      If your Pentair Water Dispenser isn't drawing brine, consider the following: * The drain line flow control may be plugged: Clean the drain line flow control. * The injector may be plugged: Clean the injector. * The injector screen may be plugged: Clean the screen. * The line pressure may be too low: Increase the line pressure to 20 psi. * There could be an internal control leak: Change the seals, spacers, and piston assembly. * The service adapter did not cycle: Check the drive motor and switches.
  • S
    Samuel KramerAug 30, 2025
    Why is my Pentair Water Dispenser using too much salt?
    • C
      Charles ThompsonAug 30, 2025
      If your Pentair Water Dispenser is using too much salt: * Check the salt usage and salt setting, as the salt setting might be improper. * Refer to the section addressing 'Excessive water in brine tank' to resolve if there's excessive water.
  • M
    Meghan MartinAug 31, 2025
    Why does the drain flow continuously on my Pentair Water Dispenser?
    • D
      Dr. Molly Miller DDSSep 1, 2025
      If the drain is flowing continuously in your Pentair Water Dispenser: * The valve may not be programming correctly: Check the timer program and positioning of control. Replace the power head assembly if not positioning properly. * There may be foreign material in the control: Remove the power head assembly and inspect the bore. Remove any foreign material and check the control in various regeneration positions. * There could be an internal control leak: Replace the seals and piston assembly.
  • S
    Sara HinesSep 2, 2025
    Why is there iron in the conditioned water from my Pentair Water Dispenser?
    • M
      Michele BrewerSep 3, 2025
      If there's iron in the conditioned water from your Pentair Water Dispenser, it might be due to a fouled mineral bed. Check the backwash, brine draw, and brine tank fill. Increase the frequency of regeneration and the backwash time.
  • R
    reyesdavidSep 4, 2025
    Why is there loss of mineral through drain line in my Pentair Water Dispenser?
    • P
      Paul OrrSep 4, 2025
      If you're experiencing a loss of mineral through the drain line of your Pentair Water Dispenser: * There might be air in the water system: Ensure that the well system has a proper air eliminator control and check for a dry well condition. * The drain line flow control may be improperly sized: Check for the proper drain rate.
  • M
    msimsSep 6, 2025
    Why does my Pentair Water Dispenser control cycle continuously?
    • C
      Christina DiazSep 6, 2025
      If your Pentair Water Dispenser control cycles continuously, it may be due to a misadjusted, broken, or shorted switch. Determine if the switch or timer is faulty and replace it, or replace the complete power head.
  • R
    Ryan JohnsonSep 8, 2025
    What does '2 - Regen Failure' mean on my Pentair Water Dispenser and how do I fix it?
    • S
      Stacey AlexanderSep 9, 2025
      To address a Regen Failure error on your Pentair Water Dispenser: Perform a Manual Regeneration to reset the error code. If the system is metered, verify that it is measuring flow by running service water and watching for the flow indicator on the display. If the unit does not measure flow, verify that the meter cable is connected properly and that the meter is functioning properly. Enter a Master Programming Mode and verify that the unit is configured properly. As appropriate for the valve configuration, check that the correct system capacity has been selected, that the day override is set properly, and that meter is identified correctly. If the unit is configured as a Day-of-Week system, verify that at least one day is set ON. Correct the settings as necessary.

Summary

Job Specification Sheet

Installation

Start-Up Instructions

Timer Features

Timer Operation

Master Programming Mode

Display Format (DF)

Sets unit of measure for volume and time display.

Valve Type (VT)

Specifies the valve's regeneration cycle type.

Control Type (CT)

Determines how the control triggers regeneration.

Unit Capacity (C)

Sets the treatment capacity of the system media.

Feedwater Hardness (H)

Sets the inlet water hardness for calculations.

Day of Week Settings

Schedules regeneration for specific days of the week.

User Programming Mode

Day Override (DO)

Adjusts the timer's day override setting for regeneration frequency.

Regeneration Time (RT)

Sets the time of day for system regeneration.

Diagnostic Programming Mode

Control Valve Assembly

Valve Powerhead Assembly

Troubleshooting

Wiring Diagram

Service Instructions