Notes:
1) The addition of chlorine (bleach) to a hot water tank that has in the past been fed with untreated
raw water with high levels of other c
ontaminants (iron, manganese, hydrogen sulphide, organics, etc.)
will
result in oxidation of these contaminants and may require repeated flushing of the hot water tank. This
contingency
must be d
ealt with independently
under the start-up procedure for any other conditioners that
may form a part of the pre-treatment
for the UV unit.
2) The above disinfection procedure will result
in a massive chlorine residual far in excess of the 0.5 to 1.0
mg/L typically present in municipally chlorinated water
and of a magnitude consistent with the minimum 50
mg/L chlorine solution recommended for the disinfection of distribution systems known to be contaminated.
Do not consume water until complete system has been flushed.
3) As the monitored systems include a 254nm UV intensity monitor, note that the introduction of the bleach
solution required for disinfection will trigger a temporary low UV condition. This is due to the fact that the
bleach physically “clouds”
the raw water. Once the bleach runs through the system, the alarm condition will
return to normal. During this sanitization process, the audible alarm condition on the controller can be
temporarily deferred by pressing the “RESET” switch for 5 seconds. By doing this, the audible alarm will be
silenced.
The system will display on the controller LED. This condition will remain for 12 hours
unless the system is manually reset as outlined on page 10 of this manual.
5
2
1
2
2
2
Re-install the housing.
Turn on the cold water
supply.
Open each faucet and all
water openings until you
smell the bleach and then
close the faucets.
6
2
1
2
2
2
Turn on the hot water supply.
Open each faucet and all
water openings until you smell
the bleach and then close the
faucets.
7
1
0
30
15
45
30 mins
2
DO NOT use water for 30
minutes.
Flush the system until no
chlorine smell is detectable
and reinstall the filters.
8
Reinstall filter cartridge.