6. For best results, use only hydraulic
uidwitharatingofSAE20forrells.
Checkuidlevelwithpumpinfullydown
position.
7. Change the hydraulic oil at least once
every three years:
a.SetPump(1)atonalevelsurface.
b. Remove the Fill Screw (A). The O-
ring (B) should come off with it.
c. Tip the pump to allow the old hy-
draulic oil to drain out of the housing
completely, and dispose of the old
hydraulic oil in accordance with local
regulations.
d. With the Pump upright, completely
llthehousingwithahighquality
hydraulic oil (not included) until the
oil just begins to run out of the oil
llhole.BeVERYCAREFULnotto
allow dirt or foreign matter into the
system.
CARE & MAINTENANCE
A
B
C
D
Fig. 5
e. Make sure the O-ring (B) is still in
place around the Fill Screw (A) and
thread the Fill Screw into the Pump
securely. Do not use thread seal
tape.
f. Firmly close the Release Valve (C) by
turning it clockwise.
g. Clean with a clean cloth using a
detergent or mild solvent.