HIGH-PERFORMANCE LAMBDA
SPECTROMETERS
Hardware Guide
UV-VIS SPECTROSCOPY

Table of Contents

Other manuals for PerkinElmer Lambda 650

Question and Answer IconNeed help?

Do you have a question about the PerkinElmer Lambda 650 and is the answer not in the manual?

PerkinElmer Lambda 650 Specifications

General IconGeneral
Photometric Accuracy±0.002 A
Baseline Flatness±0.0005 A
Light SourceDeuterium
Detector TypePhotomultiplier Tube (PMT)
Sample CompartmentStandard 10 mm cell holder
Power Requirements100-240 V, 50/60 Hz

Summary

Introduction to Lambda Spectrometers

Manual Conventions and Terminology

Defines text conventions, keyboard input, and terminology used in the manual.

Understanding Notes, Cautions, and Warnings

Explains the use of NOTE, CAUTION, and WARNING for special circumstances and alerts.

Safety Practices for Spectrometer Operation

General Safety Precautions

Lists essential safety precautions and general operating conditions for using the spectrometer.

Environmental and Electrical Safety

Details ambient conditions, electrical hazards, grounding, and safety practices for operation.

Warning Labels and Fuse Information

Illustrates warning labels and explains fuse replacement procedures for safety.

System Description and Components

Instrument Overview

Introduces the Lambda spectrometers, their spectral ranges, and key features.

Optical System Details

Describes the all-reflecting, double-monochromator optical system and its components.

Spectrometer Model Variations

Outlines differences for Lambda 1050, Sphere-only, and Detector-less systems.

Installing Your Lambda Spectrometer

Site Requirements and Unpacking

Lists site requirements and provides instructions for safely unpacking the spectrometer.

Power and PC Connectivity

Details connecting the spectrometer to power and establishing PC communication.

Software Setup and Calibration

Guides users through installing UV WinLab software and calibrating the instrument.

Accessory Installation and Component Removal

Covers installing accessories and removing key components like the detector unit.

Using the Spectrometer

Startup Procedure

Outlines the steps for powering on and initializing the spectrometer and accessories.

Sample Holder Installation and Alignment

Describes the single-cell holder and guides its installation and alignment.

Minimum Volume Applications and Purging

Discusses microcell use and the procedure for purging the instrument with inert gas.

Maintenance and Care

Daily Checks and Cleaning Procedures

Lists daily checks, cleaning procedures for covers and sample compartment.

Cell Handling and Replacement Parts

Provides guidelines for cell care and lists available replacement parts.

Lamp Replacement Procedures

Details the procedures for replacing halogen and deuterium lamps.

Appendices

WEEE Disposal Instructions

Provides instructions for the disposal of electrical and electronic equipment according to WEEE directive.

Decontamination and Cleaning Procedures

Outlines procedures for decontaminating and cleaning instruments before return or repair.

Related product manuals