OPTIMA 8000
Customer Hardware and
Service Guide
ICP OPTICAL EMISSION
Return to Document Menu

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the PerkinElmer OPTIMA 8000 and is the answer not in the manual?

PerkinElmer OPTIMA 8000 Specifications

General IconGeneral
BrandPerkinElmer
ModelOPTIMA 8000
CategoryLaboratory Equipment
LanguageEnglish

Summary

Safety and Regulatory Information

Safety Practices

Instrument Safety Practices

Covers specific safety practices for operating and maintaining the instrument.

Preparing Your Laboratory

Exhaust Vent Requirements

Details necessary specifications for the instrument's exhaust venting system.

Cooling Water Requirements

Recirculating System

Details the requirements for the recirculating chiller system.

Electrical Requirements

Optima 8000

Specifies the electrical voltage, frequency, and power consumption for the Optima 8000.

System Description

Spectrometer

Describes the instrument's optical and detection systems.

ICP Source

Explains the components of the Inductively Coupled Plasma source.

Sample Introduction System

Details the components responsible for sample delivery to the plasma.

Installation

Installation Summary

Provides an overview of the installation process and guidance for service engineer assistance.

Connecting the Gases and Cooling Water

Guides on connecting essential gas and cooling water supplies.

Connecting the PolyScience Chiller

Steps for connecting the required chiller for optimal cooling.

Maintenance

Daily Checks

Outlines essential daily checks for instrument readiness and safety.

Torch Viewing Position Alignment

Describes how to align the torch for optimal signal intensity.

Quick-Change Adjustable Torch Module

Plasma Torch

Details the components and inspection of the plasma torch assembly.

GemCone Nebulizer

Daily Cleaning of the Low-Flow GemCone Nebulizer

Routine daily cleaning steps for the low-flow GemCone nebulizer.

Peristaltic Pump

Troubleshooting

Plasma Ignition and Stability Problems

Addresses issues related to plasma ignition and stability.

RF Generator/Sample Introduction System Troubleshooting Form

Error Messages

System Error (SYSERROR) Messages for RF Generator

Lists error codes, messages, meanings, and corrective actions for the RF generator.