72 RENR2696-01
Troubleshooting Section
The ECM has been powered for at least three
seconds.
System Response:
The ECM will log the diagnostic code. The diagnostic
code may be viewed on the electronic service tool.
Possible Performance Effect:
Low power
Possible engine misfire
Troubleshooting:
Further troub
leshooting is required.
Perform the following diagnostic procedure: 5 Volt
Pressure Sens
or Supply Circuit - Test”
Results:
OK STOP.
i01798158
CID 0262 FMI 04 5v Sensor
Power Supply, Voltage Less
Than Normal
Conditions Which Generate This Code:
The Electron
ic Control Module (ECM) detects all of
the following conditions:
The ECM re ad
s signal voltage that is below normal.
The ECM has been powered for at least three
seconds.
System Response:
The ECM will log the diagnostic code. The diagnostic
code may be viewed on the electronic service tool.
Possible Performance Effect:
Low power
Possible engine misfire
Troubleshooting:
Further troubleshooting is required.
Perform the fol
lowing diagnostic procedure: 5 Volt
Pressure Sensor Circuit - Test”
Results:
OK STOP.
i01897931
CID 0266 FM I 02 Incorrect
Crank-withou
t-inject inputs
Conditions Which G enerate This Code:
The Electron
ic Control Module (ECM) detects all of
the following conditions:
The Crank Wit
hout Injection input from the normally
closed relay is above 11.5 VDC.
The Crank Wit
hout Injection input from the normally
open relay is below 0.5 VDC.
System Respo
nse:
The diagnostic code may be viewed on a display
moduleoront
he electronic service tool.
The Crank Without Injection will be disabled.
Possible Pe rformance Effect:
None
Troubleshooting:
Perform the following diagnostic procedure: “Crank
Without Injection Circuit - Test”
Results:
OK STOP.