EasyManua.ls Logo

Perkins 1104E Series - Diagnostic Functional Tests; 5 Volt Engine Pressure Sensor Supply Circuit - Test

Perkins 1104E Series
224 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
92 RENR2696-01
Troubleshooting Section
Diagnostic Fun
ctional
Tests
i01798194
5 Volt E ngine Pressure Se nso r
SupplyCircuit-Test
System Opera
tion Description:
Use this procedure under the following situation:
Use this procedure if another procedure has directed
you here. Also use this procedure if any of the
following di
agnostic codes are active:
262-03 5 Volt Sensor Power Supply voltage more
than normal
262-04 5 Volt Sensor Power Supply voltage less
than normal
The following background information is related
to this proc
edure:
The Electronic Control Module (ECM) supplies
regulated +
5 VDC to the following sensors:
J201/P201 Engine Oil Pressure Sensor
J200/P200 Intake Manifold Pressure Sensor
J40/P40 Thr
ottle Sensor
The supply for the +5 V engine pressure sensor is
routed from
the ECM through ECM engine harness
connector J1/P1 terminal 2 to terminal “A” of each
pressure sensor connector. The supply voltage is 5.0
± 0.5 VDC.
The +5 V short circuit diagnostic code is probably
caused by a
short circuit or an open circuit in the
harness. The next probable cause is a sensor and
the least probable cause is the ECM.

Table of Contents