EasyManua.ls Logo

Perkins 1204F-E44TA - Page 47

Perkins 1204F-E44TA
146 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
World-Wide Reduce Time Setting
Table 6
World-Wide Reduced Time Setting
Category 1 Fault (Tampering Dosing Interruption and Quality)
-
Normal operation Level 1 Level 2 Level 3 Override
Inducement Time
First Occurrence
None 2.5 Hours 70 minutes 50 Percent torque
Shut down or idle
Until fault heals
Cycling the keyswitch
will give 20 minutes
of full power
The system must be fault free for 40 hours before the system will reset to zero. If the fault is intermittent, and returns within the 40 hours, then
the repeat inducement time will be triggered.
The override can only be used once.
Inducement Time
Repeat Occurrence
None 5 minutes 5 minutes 50 Percent torque
Shut down or idle
Until fault heals
Cycling the keyswitch
will give 20 minutes
of full power
Inducement None None None
Notification None Emission malfunction
lamp will be on solid
Emission malfunction
lamp will flash
Emission malfunction
lamp will flash
The stop lamp will
activate
Emission malfunction
lamp will flash
Contact your Perkins dealer or your Perkins Distributor at level 1 warning, do not let the fault develop.
Table 7
World-Wide Reduced Time Setting
Category 2 Fault (Non-Tampering Dosing Interruption)
-
Normal operation Level 1 Level 2 Level 3 Override
Inducement Time
First Occurrence
None 5 Hours 5 Hours 50 Percent torque
Shut down or idle
Until fault heals
Cycling the keyswitch
will give 20 minutes
of full power
The system must be fault free for 40 hours before the system will reset to zero. If the fault is intermittent, and returns within the 40 hours, then
the repeat inducement time will be triggered.
The override can only be used once.
Inducement Time
Repeat Occurrence
None None 1 Hour 50 Percent torque
Shut down or idle
Until fault heals
Cycling the keyswitch
will give 20 minutes
of full power
Inducement None None None
Notification None Emission malfunction
lamp will be on solid
Emission malfunction
lamp will flash
Emission malfunction
lamp will flash
The stop lamp will
activate
Emission malfunction
lamp will flash
Contact your Perkins dealer or your Perkins Distributor at level 1 warning, do not let the fault develop.
Table 8
World-Wide Reduced Time Setting
Category 3 Fault (Non-Tampering NOx Control Monitoring and Impeded EGR)
-
Normal operation Level 1 Level 2 Level 3 Override
(continued)
SEBU9063-07
47
Operation Section
Selective Catalytic Reduction Warning System

Table of Contents

Other manuals for Perkins 1204F-E44TA

Related product manuals