i07222343
After Stopping Engine
Note: Before you check the engine oil, do not
operate the engine for at least 10 minutes to allow
the engine oil to return to the oil pan.
Check the crankcase oil level. Maintain the oil
level between the ADD mark and the FULL
mark on the oil level gauge.
If necessary, perform minor adjustments. Repair
any leaks and tighten any loose bolts.
Note the service hour meter reading. Perform the
maintenance that is in the Operation and
Maintenance Manual, “Maintenance Interval
Schedule”.
Fill the fuel tank to help prevent accumulation of
moisture in the fuel. Do not overfill the fuel tank.
NOTICE
Only use antifreeze/coolant mixtures recommended
in this Operation and Maintenance Manual, “Refill
Capacities and Recommendations” topic or in this
Operation and Maintenance Manual, “Fluid Recom-
mendations” topic. Failure to do so can cause engine
damage.
Allow the engine to cool. Check the coolant level.
If freezing temperatures are expected, check the
coolant for proper antifreeze protection. The
cooling system must be protected against freezing
to the lowest expected outside temperature. Add
the proper coolant/water mixture, if necessary.
Perform all required periodic maintenance on all
driven equipment. This maintenance is outlined in
the instructions from the OEM.
M0087475-06 67