EasyManua.ls Logo

Perkins 402F-05 - Page 33

Perkins 402F-05
110 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
The following parameters are monitored:
Coolant temperature
Oil pressure
Engine speed
Atmospheric pressure (Barometric pressure)
The coolant temperature, oil pressure, and the
engine speed can trigger an engine shutdown.
Atmospheric pressure (Barometric pressure) can
trigger an engine de-rate.
The atmospheric pressure sensor (Barometric
pressure sensor) can de-rate the engine. Operating
the engine and increasing the altitude will de-rate the
engine in accordance with emission regulations. The
start of the de-rate will be determined by the flash file
that is installed.
i06946627
Overspeed
402F-05 3600 Revolutions Per Minute
(RPM)
403F-07 3600 RPM
403F-11 3600 RPM
403F-15 3000 RPM
The overspeed is plus 700 RPM above the given
speed for engines shown.
i06946629
Sensors and Electrical
Components
The following sensors or switches are installed on the
402F-05, 403F-07, 403F-11, and the 403F-15
engines:
Oil pressure switch
Coolant temperature sensor
Atmospheric pressure sensor (Barometric
pressure sensor)
Speed sensor
Throttle actuator
SEBU9064-08
33
Operation Section
Overspeed

Related product manuals