c) Position shrink tubing over the bell flange above
the ribbing.
d) Heat shrink tubing evenly beginning at the bell
flange until it evenly encloses the former and
the internal adhesive protrudes on both sides
(see arrows).
75. Bundle all screen wires
without the test lead.
76. Cut screen wires (not the test lead!) to the required
length and connect with ground of the installation.
ATTENTION!
Ground the test lead separately if it is not needed.
The product can now be operated within the
installation observing all safety regulations.