EasyManua.ls Logo

Philips 223V5LSB/00 - Color Temp confirmation

Philips 223V5LSB/00
143 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
119
Meridian 5
CC170C
W8 LCD
C
C
119
Connect the signal to the monitor, the monitor displays white-picture, use CA-210 to measure the Color Temp of the
screen center and select the OSD to make sure whether the Color Temps accord with the SPEC.
CIE
coordinates
11500K
9300K
8200K
7500K
6500K/sRGB
sRGB
5000K
X
± 0.02
0.270
0.283
0.291
0.298
0.313
0.313
0.345
Y
± 0.02
0.281
0.297
0.306
0.314
0.329
0.329
0.357
6. How to enter into the factory mode:
1. Connect the VGA source and power off the monitor.
2. Press and buttons at the same time, power on the monitor, and then press the menu again;
themenu will appear on the top left corner.
3. Select the “Factory” and press the “MENU” button to enter the factory mode.