EasyManua.ls Logo

Philips 273E3LHSB/00 - Acceptance Test; Display Disturbances from External Environment; Display Disturbances to External Environment; Environmental Characteristics

Philips 273E3LHSB/00
83 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
!
78
Meridian 3
Transportation request for EU
A. Land 45‘ Truck and Trailer (800X1200mm pallet)
1584
B. Land 45‘ Truck and Trailer (1000X1200mm pallet) for UK
1456
6. Environmental Characteristics
The following sections define the interference and susceptibility condition limits that might occur between
external environment and the display device.
6.1 Susceptibility of display to external environment
Operating
- Temperature: 0 to 35 degree C
- Humidity: 80% max
- Altitude: 0 -3658 ft
- Air pressure: 600-1100 mBAR
Storage
- Temperature: -20 to 60 degree C
- Humidity: 95% max
- Altitude: 0 -12192ft
- Air pressure: 300-1100 mBAR
Note: recommend at 5 to 35qC, Humidity less than 60%.
6.2 Transportation tests
Refer to 5.15.2
6.3 Display disturbances from external environment
According to IEC 801-2 for ESD disturbances
6.4 Display disturbances to external environment
7. Reliability
7.1 Mean Time between Failures
System MTBF (Including the LCD panel and CCFL): 50,000 hrs
8. Quality Assurance Requirements
8.1 Acceptance test
According to MIL-STD-1916D Control II level
AQL: NA
(Please also refer to annual quality agreement)
Customer acceptance criteria: UAW0377/00

Table of Contents