5.2.4 How to Clear the Error Buffer
The error code buffer is cleared in the following cases:
By using the CLEAR command in the SAM menu
By using the CLEAR command in the Factory mode:
By using the following key sequence on the remote control transmitter: “062599” directly followed by the OK button.
If the contents of the error buffer have not changed for 50 hours, the error buffer resets automatically.
Note: If you exit SAM by disconnecting the mains from the television set, the error buffer is not reset.
Panel Code
Press the following key sequence on a standard RC transmitter: “062598” directly followed by MENU and “xxx”, where “xxx” is a 3 digit decimal value of the
panel type: see column “Display Code” in below tab. After resetting the Display Code, restart the set immediately.
CTN_ALT BOM# Panel Type Set Option Code
32PFS6402/12 TPT315B5-FHBN0.K S4DP2P 133