Removal of built-in rechargeable battery
The built-in rechargeable battery must only be removed by a qualied
professional when the appliance is discarded� Before removing the
battery, make sure that the appliance is disconnected from the wall
socket and that the battery is completely empty�
Note: Take any necessary safety precautions when you handle tools
to open the appliance and when you dispose of the rechargeable
battery�
Note: When you handle batteries, make sure that your hands, the
product and the batteries are dry�
Note: To avoid accidental short-circuiting of batteries after removal,
do not let battery terminals come into contact with metal objects (e�g�
coins, hairpins, rings). Do not wrap batteries in aluminum foil. Tape
battery terminals or put batteries in a plastic bag before you discard
them�
Procedure:
1 Remove the 2 rubber feet at the bottom of the parent unit�
2 Remove the 2 screws that are now visible at the bottom of the parent
unit�
3 Remove the 2 screws next to the rating label, release the belt clip and
slide open the battery compartment door�
4 Disconnect the battery connector cable (black-white-red cable)�
5 Remove the battery�
If there is no collection/recycling system for electronic products in your
country, you can protect the environment by removing and recycling the
battery before disposing the product�
Support