Reference : SGP_AVS_SW_ATLAS-05-05 Classification : COMPANY RESTRICTED
Version : 0.17 Project : ATLAS_DSW
Status : Proposed Chapter : User Manual
Date : 2006-09-12
Section : Diagnostic Software (Leco+)
© Philips Electronics N.V. 2006 Philips Semiconductors Page 41 of 124
1
Nucleus Name
DS_BE_StatisticalInformationReSet
Nucleus Number 909
Description Reset the statistical information in the bit engine by issuing a TRANSPARENT
SEND and TRANSPARENT_RECEIVE command. This nucleus is not
guaranteed to work on all connected BEs
Technical - Send the transparent BIT engine RESET_STATISTICAL_INFO command
Execution Time 2 seconds
Important note: This nucleus uses the transparent bit engine interface of the drive. It is
not guaranteed to work on all drives. Only use this nucleus if you are sure
that the drive supports this interface
User Input None
Error Number Description
90900 The command executed successfully
90901 There was a time-out while communicating
90902 The Basic Engine returned an unexpected result
90903 The BE returned an error code
90904 No acknowledge received from BE
90905 Communicating with the Basic Engine failed
Example
DS:> 909
090900:
Test OK @
2
Nucleus Name
DS_BE_ErrorLogGet
Nucleus Number 910
Description Get the error log from the bit engine by issuing a TRANSPARENT SEND and
TRANSPARENT_RECEIVE command. This nucleus is not guaranteed to work
on all connected BEs
Technical - Send the transparent BIT engine GET_ERROR and GET_FATAL
commands
- Display the returned info
Important note: This nucleus uses the transparent bit engine interface of the drive. It is
not guaranteed to work on all drives. Only use this nucleus if you are sure
that the drive supports this interface
Execution Time Less than 1 second
User Input None
Error Number Description
91000 The command executed successfully
91001 There was a time-out while communicating
91002 The Basic Engine returned an unexpected result
91003 The BE returned an error code
91004 No acknowledge received from BE
91005 Communicating with the Basic Engine failed
91006 The BE returned no info
Example
DS:> 910
Momentary errors (0-9): 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
0x00 0x00
Cumulative errors (1-9) : 0x00 0x80 0x20 0x00 0x00 0x00 0x00 0x00
0x00
Software fatal assert : 799 engineproxy.cpp
091000:
Test OK @
3
4