EasyManua.ls Logo

Philips DVDR3577H/05 - A Ctivation

Philips DVDR3577H/05
195 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Reference : SGP_AVS_SW_ATLAS-05-05 Classification : COMPANY RESTRICTED
Version : 0.17 Project : ATLAS_DSW
Status : Proposed Chapter : User Manual
Date : 2006-09-12
Section : Diagnostic Software (Leco+)
© Philips Electronics N.V. 2006 Philips Semiconductors Page 10 of 124
1
2.3 COMMAND LINE INTERFACE 2
Via the command line interface the execution of diagnostic nuclei can be controlled. 3
4
2.3.1 Set-up of physical interface components 5
Hardware required: 6
Control PC 7
One free COM port on the Control PC 8
Special cable to connect the DVD Recorder to the Control PC 9
The control PC must use the following port settings for the used COM port: 10
- 19200 bps, 11
- 8 data bits, 12
- no parity, 13
- 1 stop bit and 14
- no flow control. 15
The control PC is connected with a special cable (see chapter 4A.2) to the RS232 port of the 16
DVD Recorder. Via the same connection the ‘test pin’ will be connected to ground. Using this 17
pin the software can determine whether Diagnostic mode needs to be entered. 18
19
2.3.2 Activation 20
After power on the next text will be sent to the control PC 21
22
Factory Diagnostics and Service Software 23
DVD Video Recorder (Dec 13 2003, 10:55:37) 24
25
Version :258 Build :20031213_1030 26
Release :P1_7_b Buildtype :no 27
Baseline :I_P1_8_63 Variant :verum:dvdrw2_lib 28
29
DS:> 30
31
The first lines indicate that the DSW has been activated and contains the version and build info 32
of the DSW. The next line is the command line prompt (“DS:>”). The DSW is now ready to 33
receive commands. Please note that this text will be different on your specific variant of the 34
DVD+RW recorder product range. 35
36
2.3.3 Usage 37
The commands that can be given are the numbers of the nuclei. A command must be 38
terminated with an <ENTER> character from the control PC. When typing commands, the 39
backspace key can be used to make corrections. Apart from this one can use the Up and Down 40
arrows to browse to previous commands. 41
When one enters non-supported commands, the interface returns the command line prompt. 42
43
If the command (the nucleus number) is recognised, the nucleus is executed. Result and output 44
of an activated (and terminated) nucleus will be sent back to the control PC. 45
46
Example in case the command is correct: 47
48
DS:> 1200 49

Related product manuals