Nucleus Number 1514
Description Generate a test image using the FLI2310
Technical -
Execution Time Less than 1 second.
User Input None
Error Number Description
151400 Test image is generated successfully
151401 Failed to retrieve the hardware diversity string
151402 Failed to initialise the IIC communication
151403 The hardware was not detected although indicated by Diversity
151404 Unable to generate image
151405 Unable to initialise De-inter-lacer
Example
DS:> 1514
151400:
Test OK @
1
Nucleus Name
DS_HDMI_FLI2310_TestImageOff
Nucleus Number 1515
Description Switch of test-image generation by the FLI2310
Technical -
Execution Time Less than 1 second.
User Input None
Error Number Description
151500 Test image is turned off successfully
151501 Failed to retrieve the hardware diversity string
151502 Failed to initialise the IIC communication
151503 The hardware was not detected although indicated by Diversity
151504 Unable to initialise De-Inter-lacer
151505 IIC Error during writing DENC
Example
DS:> 1515
151500:
Test OK @
2
Nucleus Name
DS_HDMI_FLI2310_Routing
Nucleus Number 1516
Description Have the FLI2310 pass the video from its input to its output
Technical -
Execution Time Less than 1 second.
User Input None
Error Number Description
151600 Routing path is created successfully
151601 Failed to retrieve the hardware diversity string
151602 Failed to initialise the IIC communication
151603 The hardware was not detected although indicated by Diversity
151604 Unable to initialise the Chrysalis.
151605 Unable to access de-inter-lacer
Example
DS:> 1516
151600:
Test OK @
3
4