3.2. Control Panel
Fig.3.2.1 Function of Control Panel keys and indications
Fig.3.2.2 Scanner status
Note:*
This status indicates one of the following.: "Clean rollers", "Clean Reference Plates", or "Replace rollers"
To determine the specific condition, execute "Service Utility", and then check the status message.
Name Operation Remarks
1 DFS (Double-
feed Skip) key
When a double-feed occurs, push this key to continue scanning the double-feed detected
sheet and the following sheet on the Hopper.
2 Start/Stop key (1) Push this key to start scanning if you set [Wait Key] to "Manual Feed Mode" in your
application software.
(2) During scanning, push this key to stop scanning.
(3) If you push this key when a double feed occurs, the sheet that was detected as a double
feed will be ejected from the scanner without being scanned. Scanning will stop.
3 Ready Indicator This indicator shows the scanner status.
4 Error Indicator This indicator lights when an error occurs.
Ready Indicator Error Indicator Status
(Green) (Red)
ON OFF Ready
ON Blink (Slow) Caution*
OFF ON Error
Blink (Slow) OFF Sleep
Blink (Slow) Blink (Slow) Caution* / Sleep
Blink (Fast) OFF Warming up
Blink (2 times consecutively) OFF Double Feed Skip mode